LED and Luminaries Testing


Alpha Test House has built a testing facilities for LED & Luminaries Testing which is certified by ISO 9001:2015 & accredited by NABL & approved by BIS. The Laboratory is also providing BEE Regulator accepted Testing. The Objectives of BEE Standards & Labeling Program is to provide the consumer an informed choice about the energy saving and thereby the cost saving potential of the marketed household and other equipment like LED LAMPS, Color TV, Electric Geysers, Computer (Notebook/Laptops), Office Equipments (Printer, Copier, Scanner) etc.

The laboratory has installed a latest & highest reliable & branded Goniophotometer, Spectrophotometer, Integrating Sphere, LED Lamp, Led Luminaries, Led Control gear Test Instruments, CFL Test Instruments, Photometer and Colorimeter, Electrical Safety Testing, Environmental Testing, AC and DC Power Supply and etc.

The laboratory also provide Ingress Protection Testing at a competitive price including Safety testing, Vibration testing, LM79 etc.

Alpha Test House

Many products undergo a variety of tests before they reach the market. These tests include product safety testing, electromagnetic compatibility, vibration testing and many others. Products used indoors or outdoors are often tested against "ingress," that is, the product's resistance to water, dust and foreign objects. There are several reasons for ingress testing, including safety, functionality and product marketing. We provide Ingress Protection Testing in very competitive price including Safety testing, Vibration testing, LM79 etc.



Following products are covered under Compulsory Registration Scheme:

Sl. No.

Product

Indian Standard number( IS No.)

1

SELF-BALLASTED LED LAMPS FOR GENERAL LIGHTING SERVICES

IS 16102(Part 1):2012

2

DC OR AC SUPPLIED ELECTRONIC CONTROLGEAR FOR LED MODULES

IS 15885 (Part 2/Sec13) 2012+A1:  2015

3

FIXED GENERAL PURPOSE LED LUMINAIRES

IS 10322(Part 5/Sec 1):2012

4

Recessed LED Luminaries

IS 10322 (Part 5/Section 2) : 2012

5

LED Luminaries for Road and Street lighting

IS 10322 (Part 5/Section 3) : 2012

6

LED Flood Lights

IS 10322 (Part 5/Section 5) : 2013

7

LED Hand lamps

IS 10322 (Part 5/Section 6) : 2013

8

LED Lighting Chains

IS 10322 (Part 5/Section 7) : 2013

9

LED Luminaries for Emergency Lighting

IS 10322 (Part 5/Section 8) : 2013

Luminaries- Particular Requirements- Fixed General purpose Luminaries:

Specific tests performed

Standard against which tests are performed

Marking

 Cl. 6 of IS 10322 (Part5/Sec 1): 2012/ IEC 60598-2-1: 1979+ A1: 1987 Cl. 1.5 of EN 60598-2-1: 1997

Construction

Cl. 7 of IS 10322 (Part5/Sec 1): 2012/IEC 60598-2-1: 1979+ A1: 1987
Cl. 1.6 of EN 60598-2-1: 1997

Creepage Distance and Clearances

Clause 8 Of IS 10322 (Part5/Sec 1): 2012/IEC 60598-2-1: 1979+ A1: 1987
Clause 1.7 of EN 60598-2-1: 1997

Provision for Earthing

Clause 9 of IS 10322 (Part5/Sec 1): 2012/IEC 60598-2-1: 1979+ A1: 1987
Clause 1.8 of EN 60598-2-1: 1997

Terminals

IS 10322 (Part5/Sec 1): 2012 Clause 10 IEC 60598-2-1: 1979+ A1: 1987
Clause 1.9 of EN 60598-2-1: 1997

External and Internal Wiring

Clause 11 IS 10322 (Part5/Sec 1): 2012/IEC 60598-2-1: 1979+ A1: 1987 Clause 1.10             of EN 60598-2-1: 1997

Protection Against Electric shock

Clause 12 of IS 10322 (Part5/Sec 1): 2012/IEC 60598-2-1: 1979+ A1: 1987 Clause 1.11 of EN 60598-2-1: 1997

Endurance Tests and Thermal Tests

Clause 13 of IS 10322 (Part5/Sec 1): 2012/IEC 60598-2-1: 1979+ A1: 1987 Clause 1.12 of EN 60598-2-1: 1997

Resistance to Dust and Moisture

Clause 14 of IS 10322 (Part5/Sec 1): 2012/IEC 60598-2-1: 1979+ A1: 1987
Clause 1.13 of EN 60598-2-1: 1997

Insulation Resistance and Electric Strength

Clause 15 of IS 10322 (Part5/Sec 1): 2012 /IEC 60598-2-1: 1979+ A1: 1987
Clause 1.14 of EN 60598-2-1: 1997

Resistance to Heat, Fire and Tracking

IS 10322 (Part5/Sec 1): 2012 Clause 16 IEC 60598-2-1: 1979+ A1: 1987
Clause 1.15 EN 60598-2-1: 1997

Safety of Lamp Control gear Part 2: Particular Requirement Section : 13 d.c. or a.c. Supplied Electronic Control gear for LED Modules

Specific tests performed

Standard against which tests are performed

Marking

IS 15885 (Part 2/ Sec 13): 2012 IEC 61347-2-13, Ed2:2014 EN 61347-2-13: 2006,Clause No: 7

Protection against accidental contact with live parts

IS 15885 (Part 2/ Sec 13): 2012 IEC 61347-2-13, Ed2:2014 EN 61347-2-13: 2006,Clause No: 8

Terminals

IS 15885 (Part 2/ Sec 13): 2012 IEC 61347-2-13, Ed2:2014 EN 61347-2-13: 2006,Clause No: 9

Provision for Protective Earthing

IS 15885 (Part 2/ Sec 13): 2012,IEC 61347-2-13, Ed2:2014 EN 61347-2-13: 2006,Clause No: 10

Moisture Resistance and insulation

IS 15885 (Part 2/ Sec 13): 2012 IEC 61347-2-13, Ed2:2014 EN 61347-2-13: 2006,Clause No: 11

Electric Strength

IS 15885 (Part 2/ Sec 13): 2012 IEC 61347-2-13, Ed2:2014 EN 61347-2-13: 2006,Clause No: 12

Fault conditions

IS 15885 (Part 2/ Sec 13): 2012 IEC 61347-2-13, Ed2:2014 EN 61347-2-13: 2006,Clause No: 14

Construction

Clause No: 16 of IS 15885 (Part 2/ Sec 13): 2012/
IEC 61347-2-13, Ed2:2014 Clause No: 17 of
EN 61347-2-13: 2006

Creepage Distance and clearance

Clause No: 17 of IS 15885 (Part 2/ Sec 13): 2012
IEC 61347-2-13, Ed2:2014 Clause No: 18 of EN 61347-2-13: 2006,

Screws, current- carrying parts and connections

Clause No: 18 of IS 15885 (Part 2/ Sec 13): 2012/ IEC 61347-2-13, Ed2:2014 Cl. 19EN 61347-2-13: 2006,

Resistance to heat, fire and tracking

Clause No: 19 IS 15885 (Part 2/ Sec 13): 2012/Clause No: 19 IEC 61347-2-13, Ed2:2014
Clause No: 20 of EN 61347-2-13: 2006,

Self-Ballasted LED Lamps For general purpose Lighting Services ,Safety Requirements IS:16102(Part 1):2012, IEC 62560:2011+A1:2015

Specific tests performed

Standard against which tests are performed

Marking

Cl. 5 of IS:16102
(Part 1):2012/IEC 62560:2011

Interchangeability

Cl. 6 of IS:16102
(Part 1):2012/IEC 62560:2011

Protection Against accidental Contact With Live Parts

Cl. 7 of IS:16102
(Part 1):2012/IEC 62560:2011

Insulation Resistance and Electric Strength Test After Humidity

Cl. 8 of IS:16102
(Part 1):2012/IEC 62560:2011

Mechanical Strength

Cl. 9 of IS:16102
(Part 1):2012/IEC 62560:2011

Cap Temperature Rise Test

Cl. 10 of IS:16102
(Part 1):2012/IEC 62560:2011

Resistance To Heat

Cl. 11 of IS:16102
(Part 1):2012/IEC 62560:2011

Resistance to Flame and Ignition

Cl. 12 of IS:16102
(Part 1):2012/IEC 62560:2011

Fault Conditions

Cl. 13 of IS:16102
(Part 1):2012/IEC 62560:2011

Creepage Distance And Clearances

Cl. 14 of IS:16102
(Part 1):2012/IEC 62560:2011

Secondary cells and batteries containing alkaline or other non-acid electrolytes-safety requirements for portable sealed secondary cells, and for batteries made from them ,for use in portable applications IS 16046:2015,IEC 62133:2012

Specific tests performed

Standard against which tests are performed

Continuous low-ratse charging

Cl. 7.2.1 & Cl. 8.2.1
of IS 16046:2015/IEC 62133:2012

Vibration

Cl. 7.2.2 & 8.2.2
of IS 16046:2015/IEC 62133:2012

Molded case Stress

Cl. 7.2.3 & 7.2.4
of IS 16046:2015/IEC 62133:2012

Temperature cycling

Cl. 7.2.4
of IS 16046:2015/IEC 62133:2012

Incorrect installation

Cl. 7.3.1
of IS 16046:2015/IEC 62133:2012

External short circuit

Cl. 7.3.2 & 8.3.2
of IS 16046:2015/IEC 62133:2012

Free Fall

Cl. 7.3.3 & 8.3.3
of IS 16046:2015/IEC 62133:2012

Mechanical shock(crash hazards)

Cl. 7.3.4
of IS 16046:2015/IEC 62133:2012

Thermal abuse

Cl. 7.3.5 & 8.3.4
of IS 16046:2015/IEC 62133:2012

Low pressure

Cl. 7.3.7
of IS 16046:2015/IEC 62133:2012

Overcharge

Cl. 7.3.8 & 8.3.6
of IS 16046:2015/IEC 62133:2012

Force discharge

Cl. 7.3.9 & 8.3.7
of IS 16046:2015/IEC 62133:2012



Some of our Testing Photograph:

Alpha Test House

"OUR MOTIVE IS TO PROVIDE QUALITY TESTING WITHOUT ANY COMPROMISE MAINTAIN INTEGRITY BEYOND DOUBT"